Bio-rad Model EG-1 Econo™ Gradient Monitor Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Bio-rad Model EG-1 Econo™ Gradient Monitor herunter. Bio-Rad Model EG-1 Econo™ Gradient Monitor User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Instruction

Model EG-1Econo GradientMonitorInstructionManualCatalog Numbers731-8151731-8150M7318150H 2/27/1 2:05 PM Page i

Seite 2 - Warranty

74.3 Flow CellFig. 3.3. The flow cell.Inlet/Outlet Ports A male and a female luer fitting on either end of theflow cell allow rapid tubing connection.

Seite 3 - Table of Contents

8Model 1327 Econo Recorder. The cable also connects the Econo GradientMonitor to other recording devices which use banana plug connectors.Connecting t

Seite 4 - Section 1

6.1 Conductivity ModeIn the Conductivity mode, the numerical LED displays the conduc-tivity (in Siemens) of the solution in the flow cell, and the LE

Seite 5 - Introduction

104. Pass buffer B through the flow cell until the con-ductivity reading stabilizes. (A flashing CAL indi-cates the monitor is calibrating.)5. Press t

Seite 6 - Unpacking

Model EG-1 Econo Gradient Monitor Control Unit and Flow Cell: The control unit may be left on continually (power consumption is neg-ligible).Although

Seite 7 - 4.1 Front Panel Functions

12Larger or smaller than Chart recorder input Check chart recorder expected gradient voltage set incorrectly settings (See Sections profile 4.2 and

Seite 8

13Appendix AFuse ReplacementFigure A. Fuse removal.1. Disconnect unit from power source.2. Remove the fuse cover with a small-blade screwdriver or s

Seite 9 - 4.2 Rear Panel Sockets

Appendix CTechnical SpecificationsGeneralOperating mode Conductivity, in units of Siemens (SeeSection 1)Operating temperature 4-40 °CSensitivity range

Seite 10 - Fig. 3.3. The flow cell

Appendix DOrdering InformationModel EG-1 Econo Gradient Monitor731-8151 Econo Gradient Monitor, Model EG-1, with 100-120 Vpower adaptor (catalog numbe

Seite 11 - General Operation

M7318150 Rev HLife ScienceGroupWeb site www.bio-rad.com USA (800) 4BIORAD Australia 02 9914 2800 Austria (01) 877 89 01 Belgium 09-385 55 11 Brazi

Seite 12 - 6.2 Gradient Mode

WarrantyModel _________________________________________Serial Number __________________________________Date of Delivery_______________________________

Seite 13 - Section 7

Table of ContentsSection 1 Safety... 1Section 2 Introduction...

Seite 14 - Troubleshooting

Section 1SafetyDisconnect supply before servicing. No user serviceable parts inside.Refer servicing to Bio-Rad service personnel.This instrument is in

Seite 15

Section 2IntroductionFig. 1.1. Model EG-1 Econo Gradient Monitor.The Model EG-1 Econo Gradient Monitor is a high quality, easy to use,conductivity and

Seite 16 - Rear Panel Connections

Section 3UnpackingCarefully remove the contents of the shipping box, and check for anyobvious damage or problems with the instrument. Figure 2.1 shows

Seite 17 - Technical Specifications

4Section 4Description and FeaturesThe Model EG-1 Econo Gradient Monitor consists of a control unit anda flow cell. The control unit houses the electro

Seite 18 - Ordering Information

Display FunctionBar Graph In the Conductivity mode, the Bar Graph provides a graphic repre-sentation of the buffer conductivi-ty relative to the lower

Seite 19 - Laboratories

4.2 Rear Panel SocketsFig. 3.2. Rear panel sockets.The rear panel of the Model EG-1 Econo Gradient Monitor control unitcontains an On/Off power switch