BIO RAD QX200 Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Stromgeneratoren BIO RAD QX200 herunter. BIO RAD QX200 Instruction manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Software

QX200™ Droplet Reader and QuantaSoft™ Software Instruction Manual Catalog #186-4001, 186-4003

Seite 2

QX200 Droplet Reader and QuantaSoft Software Instruction Manual2 |Chapter 1 QX200 Droplet Digital PCR System1.2 System ComponentsThe system consists o

Seite 3 - Legal Notices

QX200 Droplet Reader and QuantaSoft Software Instruction Manual QX200 Droplet Reader and QuantaSoft Software Instruction Manual | 3Chapter 1 QX200 Dro

Seite 4 - Instrument Safety Warnings

Chapter 1 QX200 Droplet Digital PCR SystemQX200 Droplet Reader and QuantaSoft Software Instruction Manual4 |1.3 Droplet Digital PCR WorkflowDroplet Di

Seite 5 - PrefacePreface

QX200 Droplet Reader and QuantaSoft Software Instruction Manual | 5Chapter 1 QX200 Droplet Digital PCR SystemQX200 Droplet Reader and QuantaSoft Softw

Seite 6

Chapter 2 Using the QX200 Droplet ReaderQX200 Droplet Reader and QuantaSoft Software Instruction Manual6 |3. Place the 96-well PCR plate into the pla

Seite 7 - Contents

Chapter 2 Using the QX200 Droplet ReaderQX200 Droplet Reader and QuantaSoft Software Instruction ManualQX200 Droplet Reader and QuantaSoft Software In

Seite 8

Chapter 2 Using the QX200 Droplet ReaderQX200 Droplet Reader and QuantaSoft Software Instruction Manual8 |

Seite 9 - PCR System

QX200 Droplet Reader and QuantaSoft Software Instruction Manual | 9Chapter 2 Using the QX200 Droplet ReaderQX200 Droplet Reader and QuantaSoft Softwar

Seite 10 - 1.2 System Components

10 |Chapter 3 Using QuantaSoft Software3.1 Setup2. Enter the file name, then use the well editor (see Section 3.1.1) and experiment editor (see Sectio

Seite 11

QX100 Droplet Reader and QuantaSoft Software Instruction Manual| 11Chapter 3 Using QuantaSoft SoftwareChapter 3 Using QuantaSoft Software3.1.1 Using t

Seite 13 - Droplet Reader

12 |Chapter 3 Using QuantaSoft Software Chapter 3 Using QuantaSoft SoftwareQX200 Droplet Reader and QuantaSoft Software Instruction ManualExperiment e

Seite 14 - Base of plate holder

Chapter 3 Using QuantaSoft SoftwareQX200 Droplet Reader and QuantaSoft Software Instruction Manual3.2 Run1. Click Run in the left navigation bar to st

Seite 15 - Incorrect

Fill in Chapter Name Here on Master Page (33_man_left header/footer)QX100 Droplet Generator Instruction ManualChapter 3 Using QuantaSoft Software3.3 A

Seite 16

Fill in Chapter Name Here on Master Page (33_man_left header/footer)QX100 Droplet Generator Instruction ManualQX200 Droplet Reader and QuantaSoft Soft

Seite 17 - Software

QX200 Droplet Reader and QuantaSoft Software Instruction ManualChapter 3 Using QuantaSoft Software3.3.1 Viewing Channel Data (1D Amplitude)Click 1D Am

Seite 18 - 3.1 Setup

| 17QX200 Droplet Reader and QuantaSoft Software Instruction ManualChapter 3 Using QuantaSoft Software Chapter 3 Using QuantaSoft SoftwareChannel 1 flu

Seite 19 - 3.1.1 Using the Well Editor

Chapter 3 Using QuantaSoft Software3.3.2 Viewing Clustering Plots (2D Amplitude)Click 2D Amplitude to view the channel 1 vs. channel 2 clustering plot

Seite 20

| 19QX200 Droplet Reader and QuantaSoft Software Instruction ManualChapter 3 Using QuantaSoft Software3.3.3 Viewing Concentration Data (Concentration)

Seite 21 - Set threshold display (color)

Chapter 3 Using QuantaSoft Software3.3.5 Viewing Ratio Data (Ratio)Click Ratio to view ratio data for selected wells/samples. Use the radio buttons to

Seite 22 - 3.3 Analyze

QX200 Droplet Reader and QuantaSoft Software Instruction Manual | 21Chapter Title HereSpecifications and Maintenance44.1 SpecificationsWeight 56.

Seite 23

PrefaceBio-Rad Technical SupportFor help and technical advice, please contact the Bio-Rad Technical Support department. In the United States, the Tech

Seite 24

Fill in Chapter Name Here on Master PageQX100 Droplet Generator Instruction ManualChapter 4 Specifications and MaintenanceQX200 Droplet Reader and Qua

Seite 25

Fill in Chapter Name Here on Master PageQX100 Droplet Generator Instruction ManualChapter 4 Specifications and MaintenanceQX200 Droplet Reader and Qua

Seite 26

Appendix A Ordering InformationQX200 Droplet Reader and QuantaSoft Software Instruction Manual24 |Thermal Cyclers and Plate Sealer185 -1196 C1000 Tou

Seite 27

Appendix A Ordering InformationQX200 Droplet Reader and QuantaSoft Software Instruction Manual

Seite 30 - 4.2 Maintenance

Life ScienceGroup13-1367 0713 Sig 121210031906 Rev A US/EGBio-Rad Laboratories, Inc.Web site www.bio-rad.com USA 800 424 6723 Australia 61

Seite 31 - Ordering Information

PrefaceQX200 Droplet Reader and QuantaSoft Software Instruction Manualii |Safety and Regulatory Compliance This instrument has been tested and found t

Seite 32

QX200 Droplet Reader and QuantaSoft Software Instruction Manual | iiiPrefacePrefaceQX200 Droplet Reader and QuantaSoft Software Instruction ManualPPE

Seite 33

PrefaceQX200 Droplet Reader and QuantaSoft Software Instruction Manualiv |

Seite 34

PrefaceQX200 Droplet Reader and QuantaSoft Software Instruction ManualQX200 Droplet Reader and QuantaSoft Software Instruction Manual | vContentsChapt

Seite 35

QX200 Droplet Reader and QuantaSoft Software Instruction Manualvi |

Seite 36 - Laboratories, Inc

QX200 Droplet Reader and QuantaSoft Software Instruction Manual | 1QX200™ Droplet Digital™ PCR System11.1 IntroductionThe QX200 Droplet Digital PCR (d

Kommentare zu diesen Handbüchern

Keine Kommentare